Refrigerated Reverse Cycle Ducted Systems

Installations

Refrigerated Reverse Cycle Ducted Systems

A ducted refrigerated air conditioning and heating system delivers efficient cooling and heating to the entire home through carefully designed and strategically placed ductwork.

Components:
Outdoor condenser: This main unit is installed outside the home.
Indoor fan coil: Typically located in the roof cavity, this unit connects to the ductwork and distributes conditioned air evenly throughout each room.

The image below shows an example of how a ducted system is installed and where each component is located.

The image below illustrates a duct design engineered to match your home’s floor area and layout. This helps us balance airflow effectively and determine if zoning is needed for optimal comfort.

Below is an example of a Heatload Calculation table that is used to determine what kw size is required to Heat/Cool the home. This is a process that assist us at XRCC to give the client the correct system required for their home

 

Zones Info

Plan Name: XRCC

Unit Type: Ducted Refrigerated

 

AC

Zones

Areas

Volumes

Air Flow

Loads

MDO size

AC1

Bathroom

7.29 m2

19.67 m3

71L/s

1.02kW

235447 /Q200

AC1

Bed 1

16.15 m2

43.61 m3

157L/s

2.26kW

235448 /Q250

AC1

Bed 2

15.28 m2

41.26 m3

149L/s

2.14kW

235448 /Q250

AC1

Bed 3

12.24 m2

33.06 m3

119L/s

1.71kW

235447 /Q200

AC1

Ensuite

4.53 m2

12.23 m3

44L/s

0.63kW

235446 /Q150

AC1

Kitchen/Family/Dining

58.36 m2

157.57 m3

567L/s

8.17kW

235448 /Q250, 235448 /Q250, 235448 /Q250

AC1

Living

16.38 m2

44.22 m3

159L/s

2.29kW

235448 /Q250

AC1

Play

10.65 m2

28.74 m3

103L/s

1.49kW

235447 /Q200

AC1

Study

7.63 m2

20.61 m3

74L/s

1.07kW

235447 /Q200

AC1

WIR

10.84 m2

29.28 m3

105L/s

1.52kW

235447 /Q200

 

 

 

 

 

 

 

AC

Zones

Areas

Volumes

Air Flow  100%

 Total Loads  100%

MDO size

AC1

10

159.35 m2

430.25 m3

1549L/s

22.31kW

235447 /Q200,235448 /Q250,235448 /Q250,235447 /Q200,235446 /Q150,235448 /Q250, 235448 /Q250, 235448 /Q250,235448 /Q250,235447 /Q200,235447 /Q200,235447 /Q200

Total

10

159.35 m2

430.25 m3

1549L/s

22.31kW

235447 /Q200,235448 /Q250,235448 /Q250,235447 /Q200,235446 /Q150,235448 /Q250, 235448 /Q250, 235448 /Q250,235448 /Q250,235447 /Q200,235447 /Q200,235447 /Q200

Request Installation

We are ready to serve you

Your Trusted Service

Get in touch

Contact Us

Address

Ground Floor/470 St Kilda Rd,
Melbourne VIC 3004

Call us