Refrigerated Reverse Cycle Ducted Systems
Installations
Refrigerated Reverse Cycle Ducted Systems
A ducted refrigerated air conditioning and heating system delivers efficient cooling and heating to the entire home through carefully designed and strategically placed ductwork.
Components:
Outdoor condenser: This main unit is installed outside the home.
Indoor fan coil: Typically located in the roof cavity, this unit connects to the ductwork and distributes conditioned air evenly throughout each room.
The image below shows an example of how a ducted system is installed and where each component is located.
The image below illustrates a duct design engineered to match your home’s floor area and layout. This helps us balance airflow effectively and determine if zoning is needed for optimal comfort.
Below is an example of a Heatload Calculation table that is used to determine what kw size is required to Heat/Cool the home. This is a process that assist us at XRCC to give the client the correct system required for their home
Zones Info
Plan Name: XRCC
Unit Type: Ducted Refrigerated
|
AC |
Zones |
Areas |
Volumes |
Air Flow |
Loads |
MDO size |
|
AC1 |
Bathroom |
7.29 m2 |
19.67 m3 |
71L/s |
1.02kW |
235447 /Q200 |
|
AC1 |
Bed 1 |
16.15 m2 |
43.61 m3 |
157L/s |
2.26kW |
235448 /Q250 |
|
AC1 |
Bed 2 |
15.28 m2 |
41.26 m3 |
149L/s |
2.14kW |
235448 /Q250 |
|
AC1 |
Bed 3 |
12.24 m2 |
33.06 m3 |
119L/s |
1.71kW |
235447 /Q200 |
|
AC1 |
Ensuite |
4.53 m2 |
12.23 m3 |
44L/s |
0.63kW |
235446 /Q150 |
|
AC1 |
Kitchen/Family/Dining |
58.36 m2 |
157.57 m3 |
567L/s |
8.17kW |
235448 /Q250, 235448 /Q250, 235448 /Q250 |
|
AC1 |
Living |
16.38 m2 |
44.22 m3 |
159L/s |
2.29kW |
235448 /Q250 |
|
AC1 |
Play |
10.65 m2 |
28.74 m3 |
103L/s |
1.49kW |
235447 /Q200 |
|
AC1 |
Study |
7.63 m2 |
20.61 m3 |
74L/s |
1.07kW |
235447 /Q200 |
|
AC1 |
WIR |
10.84 m2 |
29.28 m3 |
105L/s |
1.52kW |
235447 /Q200 |
|
|
|
|
|
|
|
|
|
AC |
Zones |
Areas |
Volumes |
Air Flow 100% |
Total Loads 100% |
MDO size |
|
AC1 |
10 |
159.35 m2 |
430.25 m3 |
1549L/s |
22.31kW |
235447 /Q200,235448 /Q250,235448 /Q250,235447 /Q200,235446 /Q150,235448 /Q250, 235448 /Q250, 235448 /Q250,235448 /Q250,235447 /Q200,235447 /Q200,235447 /Q200 |
|
Total |
10 |
159.35 m2 |
430.25 m3 |
1549L/s |
22.31kW |
235447 /Q200,235448 /Q250,235448 /Q250,235447 /Q200,235446 /Q150,235448 /Q250, 235448 /Q250, 235448 /Q250,235448 /Q250,235447 /Q200,235447 /Q200,235447 /Q200 |